{"product_id":"smith-nephew-renasys-y-connector-npwt","title":"Smith \u0026 Nephew RENASYS Y-Connector NPWT","description":"\u003ch1 class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSmith \u0026amp; Nephew RENASYS Y-Connector for Negative Pressure Wound Therapy Systems\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2 class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eY-Connector for Managing Multiple Wounds with a Single NPWT Pump\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eProduct Description\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003e\u003cspan\u003eManaging multiple wound sites with negative pressure wound therapy (NPWT) can present a logistical challenge. Connecting more than one dressing to a single pump typically requires a reliable way to split the vacuum without compromising therapy delivery or triggering false alarms. Without the correct connector, clinicians may struggle to maintain an effective seal across both wounds, leading to interruptions in therapy and increased monitoring demands\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003e\u003cspan\u003eThe Smith \u0026amp; Nephew RENASYS Y-Connector is designed to address these needs. This accessory allows one or two wounds to be connected to a single RENASYS NPWT pump through two RENASYS Soft Ports and\/or drains . The Y-connector is specifically indicated for use with the RENASYS system to help facilitate wound healing by aspirating fluids, including body fluids, irrigation, wound exudates, and infectious substances . It is classified as a Class IIb medical device and is listed with the FDA as part of the RENASYS TOUCH system\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003e\u003cspan\u003eThis Smith \u0026amp; Nephew connector is designed for clinical flexibility. When utilizing a Y-connector, clinicians must ensure the pump's Y-Connector mode is activated to manage the therapy correctly across both dressings . It is important to note that when using a Y-connector, the pump will only detect a blockage if both connections are blocked, so regular visual monitoring of both dressings is required to confirm therapy is being delivered to each site . The connector is compatible with the RENASYS TOUCH and RENASYS EDGE systems\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eFeatures\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDual-Wound Connection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e Allows one or two wounds to be connected to a single RENASYS NPWT pump via two Soft Ports and\/or drains, simplifying therapy for patients with multiple wound sites \u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"9\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eRENASYS System Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e Specifically designed for use with Smith \u0026amp; Nephew RENASYS Negative Pressure Wound Therapy systems, including the RENASYS TOUCH and RENASYS EDGE pumps \u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"11\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eFacilitates Fluid Aspiration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e Supports the NPWT process by helping to aspirate fluids, exudates, and infectious substances from the wound bed \u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"12\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eClass IIb Medical Device:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e Manufactured to appropriate regulatory standards for advanced wound management accessories \u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"13\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eRequires Y-Connector Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e For correct therapy management, the pump must be set to Y-Connector mode when two dressings are attached\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cspan class=\"\"\u003eWhy Choose Smith \u0026amp; Nephew\u003c\/span\u003e\u003c\/h5\u003e\n\u003col\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eBetter than makeshift solutions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eUsing a non-compatible or improvised connector can compromise the vacuum seal and may not integrate correctly with the RENASYS pump's safety and alarm systems. The RENASYS Y-Connector is purpose-built for the system, ensuring proper fit and function for managing multiple wounds \u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"16\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDesigned for clinical safety and monitoring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe connector is part of a system designed with specific clinical protocols in mind. When used correctly with the Y-Connector mode activated, it allows a single pump to manage two dressings. However, because the pump may not detect a blockage in just one of the two connected dressings, the design necessitates regular visual monitoring to ensure both wounds are receiving therapy, supporting safe clinical practice \u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"18\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eReliable system integration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eAs an official Smith \u0026amp; Nephew accessory, the Y-Connector ensures seamless integration with the RENASYS platform, allowing clinicians to confidently expand therapy to multiple sites without introducing incompatible components\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Diabetic Pro","offers":[{"title":"Default Title","offer_id":68091692351808,"sku":"SN-5466020971","price":26.45,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/5661\/6512\/files\/d9a4ac9da75c47179659a8d03df4246b__51175.1792789062.380.380.jpg?v=1794433234","url":"https:\/\/diabeticpro.com\/products\/smith-nephew-renasys-y-connector-npwt","provider":"Diabetic Pro","version":"1.0","type":"link"}